{"product_id":"mejdaf-622","title":"Fluke 1760TR Three-Phase Power Quality Recorder","description":"\u003cp\u003e\u003cb\u003eClass-A compliance for the most demanding power quality tests\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe\u003cb\u003e \u003c\/b\u003eFluke 1760 Three-Phase Power Quality Recorder is fully compliant to IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium- and low-voltage networks, this power quality monitor provides the flexibility to customize thresholds, algorithms, and measurement selections. The 1760 power recorder captures the most comprehensive details on user-selected parameters.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDetailed disturbance analysis\u003c\/b\u003e – Perform high-speed transient analysis and uncover root cause of equipment malfunction for later mitigation and predictive maintenance. The fast transient option, with its 6000 V measurement range, allows capture of very short impulses such as lightning strikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eClass-A quality-of-service compliance\u003c\/b\u003e – Validate incoming power quality at the service entrance. Thanks to Class A compliance, the Fluke 1760 allows undisputable verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEvent correlation at multiple locations\u003c\/b\u003e – Utilizing GPS time synchronization, users can quickly detect where a fault occurred first, either inside or outside the facility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGalvanic separation and DC coupling\u003c\/b\u003e – Allows complete measurements on dissimilar power systems. For example troubleshoot UPS systems by simultaneously recording the battery voltage and power output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower quality and power load studies\u003c\/b\u003e – Assess baseline power quality to validate compatibility with critical systems before installation and verify electrical system capacity before adding loads.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cli\u003e\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eFully Class-A compliant: \u003c\/b\u003eConduct tests according to the stringent international IEC 61000-4-30 Class-A standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGPS time synchronization: \u003c\/b\u003eCorrelate data with events or datasets from other instruments with precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFlexible and fully configurable thresholds and scale factors: \u003c\/b\u003eAllows user to pinpoint specific issues by defining the detailed criteria for detection and recording of disturbances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUninterrupted power supply (40 minutes): \u003c\/b\u003eNever miss important events - even record the beginning and end of interruptions and outages to help determine the cause\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e10 MHz, 6000 Vpk waveform capture: \u003c\/b\u003eGet a detailed picture of even the shortest event\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e2 GB data memory: \u003c\/b\u003eEnables detailed, simultaneous recording of numerous power parameters for long periods of time\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eComprehensive software included: \u003c\/b\u003eProvides trend diagrams for root cause analysis, statistical summaries, report writing and real-time data monitoring in the online mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePlug and play: \u003c\/b\u003eAllows quick setup with automatic sensor detection; sensors are instrument powered, eliminating the need for batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRugged field design: \u003c\/b\u003eInsulated housing and a solid state design with no rotating components enable reliable testing under nearly any conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower quality statistics according to EN50160\u003c\/li\u003e\n\u003cli\u003eVoltage event list (dips, swells and interruptions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eContinuous recording of:\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eCurrent\u003c\/li\u003e\n\u003cli\u003ePower P, Q, S\u003c\/li\u003e\n\u003cli\u003ePower factor\u003c\/li\u003e\n\u003cli\u003ekWh\u003c\/li\u003e\n\u003cli\u003eFlicker\u003c\/li\u003e\n\u003cli\u003eUnbalance\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003cli\u003eVoltage and current harmonics to the 50th \/ Interharmonics\u003c\/li\u003e\n\u003cli\u003eTHD\u003c\/li\u003e\n\u003cli\u003eMains signaling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eTriggered recordings\u003c\/b\u003e\u003c\/li\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cli\u003e\u003cb\u003eOnline mode (Oscilloscope, transients and events)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eFast transient analysis up to 10 MHz\u003c\/b\u003e\u003c\/li\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cli\u003e\u003cb\u003e4, 600 V voltage probes\u003c\/b\u003e\u003c\/li\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cli\u003e\u003cb\u003e4 dual-range flexible current probes (1000 A \/ 200 A AC)\u003c\/b\u003e\u003c\/li\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cli\u003e\u003cb\u003eGPS time sync receiver\u003c\/b\u003e\u003c\/li\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cli\u003e\u003cb\u003e2 GB Flash Memory\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/li\u003e\u003cli\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cspan\u003eOverview of Measurement Functions\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatistical evaluation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePower quality statistics according to EN50160 and DISDIP tables like ITIC, CEBEMA, ANSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEvent list\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDips, swells and interruptions are detected and stored in the event list. Also any trigger which fires generates an event added to this list.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eThe Event list shows the exact time when the event occurred as well as the duration and magnitude. Sorting by several attributes of these events is possible to select one for further root cause analysis.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eRMS values, transients and fast transients can be stored if a trigger fires\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous recording\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFluke 1760 records rms values together with corresponding minimum and maximum values for:\u003cbr\u003e• Voltage\u003cbr\u003e• Current\u003cbr\u003e• Power P, Q, S\u003cbr\u003e• Power Factor\u003cbr\u003e• kWh\u003cbr\u003e• Flicker\u003cbr\u003e• Unbalance\u003cbr\u003e• Frequency\u003cbr\u003e• Harmonics\/Interharmonics continuously with the following time aggregations: Day, 10 min, Free Interval, e.g.: 15 min, 2 h\u0026lt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eTriggered recordings\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cb\u003erms\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAggregation time is adjustable between 10 ms (1\/2 cycle), 20 ms (1 cycle), 200ms (10\/12 cycles) or 3 sec (150\/180 cycles).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eCalculating rms values, Harmonics and Interharmonics is performed synchronous to the power frequency.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eBasic aggregation for harmonics and interharmonics is 200ms\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOscilloscope\u003c\/td\u003e\n\u003ctd\u003eSample rate is 10.24 kHz for all 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Transients\u003c\/td\u003e\n\u003ctd\u003eSample rate is selectable from 100 kHz to 10 MHz for channel 1-4 FFT of Fast Transients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains signalling\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePhases and N-conductor, Voltage and current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnline mode\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVariable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cspan\u003eGeneral Data\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic uncertainty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003erefers to reference conditions and is guaranteed for two years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003edeveloped, manufactured as per ISO 9001: 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"7\"\u003eEnvironment conditions\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating temp. range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +50°C; 32°F to +122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temp. range\u003c\/td\u003e\n\u003ctd\u003e-20°C to +50°C; -4°F to +122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temp. range\u003c\/td\u003e\n\u003ctd\u003e20°C to +60°C; -4°F to 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference temperature\u003c\/td\u003e\n\u003ctd\u003e23°C ±2 K; 74°F ±2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic class\u003c\/td\u003e\n\u003ctd\u003eB2 (IEC 654-1), -20°C to +50°C; -4°F to +122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMax. operating altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m: max. 600 V CAT IV\u003cspan\u003e1\u003c\/span\u003e, power supply: 300 V CAT III 5000 m: max 600 V CAT III\u003cspan\u003e1\u003c\/span\u003e, power supply: 300 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e1. Depending on sensor\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eReference conditions\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eEnvironment temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e23°C ±2 K ; 74°F ±2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e230 V ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal\u003c\/td\u003e\n\u003ctd\u003edeclared input voltage \u003ci\u003eU\u003c\/i\u003edin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAveraging\u003c\/td\u003e\n\u003ctd\u003e10 minute intervals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInsulated, robust plastics housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEMC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eEmission\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eClass-A as per IEC\/EN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003ePower supply\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAC: 83 V to 264 V, 45 to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eDC: 100 V to 375 V\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61010-1 2nd edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e300 V CAT III\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003eNIMH, 7.2 V, 2.7 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack\u003c\/td\u003e\n\u003ctd\u003eIn case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged accumulators the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFluke 1760 features LED indicators for the status of the 8 channels, phase sequence, power supply (mains or accumulator), memory usage, time synchronization, and data transfer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower LED\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003ePermanent light: normal power supply from mains.\u003c\/li\u003e\n\u003cli\u003eOFF: supply via internal accumulator in case of a power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel LEDs 3-color LEDs per channel for\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003eoverload condition\u003c\/li\u003e\n\u003cli\u003eunder load condition\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 GB Flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory model\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLinear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEthernet (100 MB\/s), compatible to Windows® XP, 7 and 8, RS 232, external modem via RS 232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud rate for RS 232\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9600 Baud to 115 kBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e325 x 300 x 65 mm; 2.8 x 11.8 x 2.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eappr. 4.9 kg; 10.8 lbs. (without accessories)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration interval\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 year recommended for Class-A, otherwise 2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cspan\u003eSignal Conditioning\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange for 50 Hz systems\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 Hz ±15% (42.5 Hz to 57.5 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange for 60 Hz systems\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60 Hz ±15% (51 Hz to 69 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e16 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/li\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":67636273217750,"sku":"Fluke 1760TR","price":139276.5,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/5800\/4694\/files\/1760-01a-600x402-500x554_cc014f74-3151-4f9a-99fc-91c64ee286f3.jpg?v=1792320213","url":"https:\/\/safebox.sa\/en\/products\/mejdaf-622","provider":"SafeBox Company - شركة الصندوق الامن","version":"1.0","type":"link"}