{"product_id":"mejdaf-675","title":"Fluke 190-504 500MHz ScopeMeter® Test Tool","description":"\u003cp\u003e\u003cb\u003eWhy choose the new 500 MHz four-channel ScopeMeter® test tool?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eA faster sample rate and higher bandwidth means greater accuracy and clarity. The scope will capture and display unknown waveform shapes, amplitudes and any disturbances. In order to display at least the fifth harmonic component of a signal, a good rule of thumb is to select a scope with a bandwidth of at least five times the maximum clock rate of the device under test. The faster the sample interval, the more accurate and detailed the scope will display a signal edge (dV\/dt) and peaks of any reflections or transients.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003csection\u003e\u003c\/section\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cb\u003eSee more, fix more with the four-channel CAT IV rated Fluke ScopeMeter 190-504\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke ScopeMeter 190 Series II combines the highest safety ratings and rugged portability with the high performance of a bench oscilloscope. Designed for plant maintenance engineers and technicians, these tough ScopeMeter test tools go into harsh, dirty, and hazardous industrial conditions to test everything from microelectronics to power electronics applications.\u003c\/p\u003e\n\u003cp\u003eThe 190 Series II is the one test tool you will reach for to tackle just about any troubleshooting task. They include a multimeter, TrendPlot™ and ScopeRecord™ roll paperless recorder modes and hands free operation with Connect-and-View™ triggering, and much more:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFour electrically isolated inputs\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V \/ CAT IV 600 V safety rated\u003c\/li\u003e\n\u003cli\u003eChoose from 60 MHz, 100MHz, 200MHz or 500MHz bandwidth models\u003c\/li\u003e\n\u003cli\u003eFast sampling rate, up to 5 GS\/s with up to 200 ps resolution (Depending on model and channels used)\u003c\/li\u003e\n\u003cli\u003eDeep memory: 10,000 samples per channel waveform capture so you can zoom in on the details\u003c\/li\u003e\n\u003cli\u003eDedicated 999 Count digital multimeter.\u003c\/li\u003e\n\u003cli\u003eFour meter measurements via scope BNC inputs in four-channel models\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ continuous auto-trigger, single shot, pulse width, and video triggering\u003c\/li\u003e\n\u003cli\u003eScopeRecord roll mode, capture waveform sample data for up to 48 hours\u003c\/li\u003e\n\u003cli\u003eTrendPlot, trend measurement readings for up to 22 days\u003c\/li\u003e\n\u003cli\u003eAdvanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V\/s, w\/s)\u003c\/li\u003e\n\u003cli\u003eIP-51 rated for dust and drip proof to withstand harsh environments\u003c\/li\u003e\n\u003cli\u003eIsolated USB ports for memory devices and PC connectivity\u003c\/li\u003e\n\u003cli\u003eLi-Ion battery for extended operating timespan:\u003cul\u003e\n\u003cli\u003e190-X04, four-channel models up to 7 hour (BP291 included standard)\u003c\/li\u003e\n\u003cli\u003eCharge spare battery using optional external battery charger EBC290\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasy-access battery door to make it easy to swap batteries\u003c\/li\u003e\n\u003cli\u003eA handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eGain four times the diagnostic power plus CAT IV safety rating\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eTheFluke ScopeMeter 190-504 portable scopes are double-insulated four-channel floating oscilloscopes, safety rated for measurements in CAT III 1000 V\/CAT IV 600 V environments.\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e\u003ca href=\"http:\/\/assets.fluke.com\/demo-SCOPE\/3950967_Ind_elec_diagram.html\"\u003eThree-dimensional testing for industrial systems »\u003c\/a\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eInspect input signals, output feedback loops or safety interlocks simultaneously to find a range of problems including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCircuit voltage\/current overloading\u003c\/li\u003e\n\u003cli\u003eSignal timing measurements and synchronization issues\u003c\/li\u003e\n\u003cli\u003eAttenuation\/input impedance mismatch\u003c\/li\u003e\n\u003cli\u003eSignal fluctuation\/drift\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/assets.fluke.com\/demo-SCOPE\/3950967_Ind_elec_diagram.html\"\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/scope_ind-electronics-diagram_200p.gif\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e\u003ca href=\"http:\/\/assets.fluke.com\/demo-SCOPE\/3950597_three-phase_diagram.html\"\u003eThree-phase testing for diagnosing VSD, power inverters, and converters »\u003c\/a\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest for harmonics, transients and loads at the three-phase power input\u003c\/li\u003e\n\u003cli\u003eTroubleshoot dc to ac converters for faulty IGBT gates or filter circuits\u003c\/li\u003e\n\u003cli\u003eTest PWM output for reflections and transients or voltage unbalance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/assets.fluke.com\/demo-SCOPE\/3950597_three-phase_diagram.html\"\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/three-phase-electronic-systems_200p.gif\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eSafely measure from mV to kV\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eStandard probes that cover a wide application range from mV to kV prepare you for anything from micro-electronics to heavy duty medium voltage electrical applications. Independent isolated inputs eliminate the risk of accidental ground short circuits by allowing you to make measurements in mixed circuits with separate ground references.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTake on the harshest conditions with the only IP-51-rated according to IEC60529 scope on the market\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eRugged and shock-proof, all ScopeMeter portable oscilloscopes are built for harsh environments. Their sealed cases protect them from dust, water vapor, drips, humidity and airborne pollutants, ensuring reliable and accurate performance every time you need them.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/F-190-204_06b_s_200x245px.jpg\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eBuilt in digital multimeter to quickly and conveniently perform precise measurements\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eBuilt-in digital multimeter 2-channel models with isolated dual input scope and dedicated digital multimeter. Conveniently switch from waveform analysis to precise multimeter measurements using the built in 5000 count digital multimeter. Measurement functions include VDC, VAC, VAC + DC, resistance, continuity and diode test. Measure current and temperature using a suitable shunt, probe or adapter with wide range of scaling factors. The Fluke-190-504, 4 channel models incorporate four meter measurements via the 4 channel scope BNC inputs.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/MeterMode_328x245px.jpg\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eWork a full shift on a single charge\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNew high-performance batteries take advantage of Li-Ion technology to keep you going strong for up to seven hours. And with the easy-access battery door you can make battery swaps fast.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/F-190-204_04a_328px_x_220px.jpg\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eCapture and share waveforms easily with new USB connectivity\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eTwo USB ports, electrically isolated from measurement input circuits offer you easy USB connectivity to a PC or USB memory devices. Store unlimited waveforms, screen captures or instrument setups to a USB memory device. Connect to a PC USB interface to transfer and archive critical measurement data using FlukeView software for windows.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/F-190-204_07_328px_x_220px.jpg\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eSee a stable display instantly with connect-and-view™ triggering\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eConnect-and-View™ automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable, and repeatable display of virtually any signal including motor drive and control signals. Expedites measuring several test-points in rapid succession.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u003cspan\u003e\u003cimg src=\"http:\/\/assets.fluke.com\/images\/Products\/Scopemeter\/190-II\/connect_view_screen_200p.gif\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eRecord up to 48 hours of high-resolution waveforms with ScopeRecord™\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eScopeRecord memory stores up to 30,000 data points per channel, capturing intermittents and fast glitches.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStores events like motion profiles, UPS power up signals, power supply AC and DC signals, and motor start-ups\u003c\/li\u003e\n\u003cli\u003eWith the Stop-on-Trigger mode, the ScopeMeter 190-504 automatically recognizes a power failure and stores the waveform data preceding it\u003c\/li\u003e\n\u003cli\u003eWith the waveform zoom you can look at the smallest details like individual power cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u003cspan\u003e\u003cimg src=\"http:\/\/assets.fluke.com\/images\/Products\/Scopemeter\/190-II\/ScopeRecord_screen_200p.gif\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eRecord up to 22 days with Trendplot™ paperless recorder to find intermittent faults\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eIntermittent faults can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Line outages, sags, or starting and stopping a motor can also cause a machine to stop. The TrendPlot function in the Fluke ScopeMeter test tool helps find those faults by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePlotting minimum and maximum peak values and average over time up to 22 days\u003c\/li\u003e\n\u003cli\u003ePlotting any combination of voltages, amps, temperature, frequency and phase for all four inputs, all with time and date stamp to pinpoint faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of channels\u003c\/td\u003e\n\u003ctd\u003e500 MHz: 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-time sample rate\u003c\/td\u003e\n\u003ctd\u003e5 GS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e4x BNc input scope plus DMM input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndependently floating isolated inputs\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V CAT III\/600 V CAT IV between inputs, references and ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput sensitivity\u003c\/td\u003e\n\u003ctd\u003e2 mV-100 V\/div plus variable attentuation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger types\u003c\/td\u003e\n\u003ctd\u003eConnect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger source\u003c\/td\u003e\n\u003ctd\u003e4x BNC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlitch capture\u003c\/td\u003e\n\u003ctd\u003e8 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eScope measurements\u003c\/td\u003e\n\u003ctd\u003eCursor: 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eAutomatic: 30\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMaximum record length\u003c\/td\u003e\n\u003ctd\u003eScopeRecord mode: 30,000 pts per input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eScope mode: 10,000 pts per input\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePersistence\u003c\/td\u003e\n\u003ctd\u003eDigital persistence giving analog oscilloscope-like waveform decay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform compare\u003c\/td\u003e\n\u003ctd\u003eWaveform reference with automatic Pass\/Fail testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eDMM Specification\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter inputs \u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eBNC inputs function as DMM input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurements\u003c\/td\u003e\n\u003ctd\u003eVDC, VAC rms, VAC + DC rms, Current (through clamp or shunt), Temperature °C or °F (using optional converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eScreen + Setup: 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eRecording: 10\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e153 mm full color LCD with fast update rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eEnvironmental Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C Including Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e0°C to 50°C Excluding Batteries\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 2,000 m (6666 ft) for CAT IV 600 V\/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eUp to 3,000 m (10,000 ft) for CAT III 600 V\/ CAT II 1000 V\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eSafety Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety\u003c\/td\u003e\n\u003ctd\u003e1,000 V CAT III\/600 V CAT IV (EN61010-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/li\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":67636273938646,"sku":"Fluke 190-504","price":40127.64,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/5800\/4694\/files\/190-204-01b-600x402-500x554_e60f7cf3-d14b-4b4e-ba52-beeaff9c2fbd.jpg?v=1792320243","url":"https:\/\/safebox.sa\/en\/products\/mejdaf-675","provider":"SafeBox Company - شركة الصندوق الامن","version":"1.0","type":"link"}