{"product_id":"mejdaf-689","title":"Fluke 3000 FC HVAC System","description":"\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\n\u003cp\u003e\u003cb\u003eThe Fluke FC Wireless HVAC System lets you work on electrical panels faster, safer, easier with remote current and temperature modules\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eConnect your FC AC Wireless Current Clamp Module to your test point, and view the results up to 20 meters away on the FC Wireless Digital Multimeter. Plus, you can connect the t3000 FC Wireless K-Type wireless temperature module and view remote temperature measurements.\u003c\/p\u003e\n\u003cp\u003eYou’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements.\u003c\/p\u003e\n\u003cp\u003eFrom short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the Fluke Connect remote modules captures up to 65,000 sets of time stamped min\/max\/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.\u003c\/p\u003e\n\u003cp\u003eNow you can take readings on moving machinery, with only the measurement module in harm’s way.\u003c\/p\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cdiv\u003e\n\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cb\u003eThe Fluke 3000 FC HVAC System provides measurement of all common electrical parameters\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC voltage measurements to 1000 V\u003c\/li\u003e\n\u003cli\u003eAC and DC current with 0.01 mA resolution\u003c\/li\u003e\n\u003cli\u003eContinuity, resistance, diode test, capacitance and frequency measurements\u003c\/li\u003e\n\u003cli\u003eMIN\/MAX recording\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, Cat IV 600 V; IP54\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS AC clamp meter\u003c\/li\u003e\n\u003cli\u003eMeasure up to 400 A AC\u003c\/li\u003e\n\u003cli\u003eUse as a standalone meter or as part of the system\u003c\/li\u003e\n\u003cli\u003eLogging function for recording and saving up to 65,000 readings\u003c\/li\u003e\n\u003cli\u003eInrush function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith the Fluke t3000 FC Wireless K-Type Temperature Module you can:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse as a standalone meter or as part of the system\u003c\/li\u003e\n\u003cli\u003eLogging function for recording and saving up to 65,000 readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\n\u003ch4\u003eFluke 3000 FC Series Wireless Multimeter\u003c\/h4\u003e\n\u003cp\u003e* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [Number of least significant digits]).\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eDetailed Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eAC Voltage\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange ¹ \/ Resolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e600.0 mV \/ 0.1 mV\u003cbr\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy \u003cspan\u003e2\u003c\/span\u003e \u003cspan\u003e3\u003c\/span\u003e \u003cspan\u003e4\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e45 Hz to 500 Hz\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e1. All AC voltage ranges are specified from 1% of range to 100% of range. \u003cbr\u003e2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor \u0026lt; 1.5 at 1000 V.\u003cbr\u003e3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. \u003cbr\u003e4. Do not exceed 107 V-Hz.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eDC Voltage, Continuity, Resistance, Diode Test and Capacitance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eFunction\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emV\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.09% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eV\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V \u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.09% + 2\u003cbr\u003e0.15% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e)))\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMeter beeps at \u0026lt; 25 Ω, beeper detects opens or shorts of 250 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eΩ\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e60.00 kΩ \/ 0.1 kΩ\u003cbr\u003e600.0 kΩ \/ 0.001 MΩ\u003cbr\u003e50.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.5% + 2\u003cbr\u003e0.5% + 1\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.000 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eµF\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF\u003cspan\u003e1 \/ \u003c\/span\u003e1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.2% + 2\u003cbr\u003e10% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e\n\u003cspan\u003e1\u003c\/span\u003e In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eAC and DC Current\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eFunction\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA AC \u003cbr\u003e(45 Hz to 1 kHz)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eRange \u003cspan\u003e1\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e \/ Resolution\u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA \u003cspan\u003e3\u003c\/span\u003e\/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA DC \u003cspan\u003e2\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \u003cspan\u003e1\u003c\/span\u003e \/ Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA \u003cspan\u003e3\u003c\/span\u003e\/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e1. All AC current ranges are specified from 5% of range to 100% of range. \u003cbr\u003e2. Input burden voltage (typical): 400 mA input 2 mV\/mA. \u003cbr\u003e3. 400.0 mA accuracy specified up to 600 mA overload.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eFrequency\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange \/ Resolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 kHz\u003cbr\u003e99.99 kHz \/ 0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy \u003cspan\u003e1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e\n\u003cspan\u003e1\u003c\/span\u003e Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eInput Characteristics\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload \u003cbr\u003eprotection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInput impedance \u003cbr\u003e(nominal)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cb\u003eCommon mode rejection ratio (1 kΩ unbalance)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eNormal mode rejection\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/function-1.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/function-2.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB, DC to 60 Hz\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/function-3.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"3\"\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull scale voltage\u003c\/td\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTo 6 MΩ\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/function-4.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 VDC\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 VDC\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.9 VDC\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/function-5.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 VDC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.000 VDC\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003emA Function\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eFused, 44\/100 A, 1000 V FAST Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eOverload\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":67636274200790,"sku":"Fluke 3000 FC HVAC","price":0.0,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/5800\/4694\/files\/F-3000fc-hvac_01b_600x402-500x554.jpg?v=1792320257","url":"https:\/\/safebox.sa\/en\/products\/mejdaf-689","provider":"SafeBox Company - شركة الصندوق الامن","version":"1.0","type":"link"}