{"product_id":"mejdaf-691","title":"Fluke 3000 FC Series Wireless Multimeter","description":"\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\n\u003cp\u003eAll the facts, right in the field. The Fluke 3000 FC True-RMS Wireless Multimeter with the Fluke Connect™ app and ShareLive™ video call.\u003c\/p\u003e\n\u003cp\u003eWith its precision, reliability and ease of use, the Fluke 3000 FC Wireless Multimeter is the ideal solution for professional technicians. Independently tested for safe use in CAT IV 600V\/ CAT III 1000 V environments, the Fluke 3000 FC has all the features you need to troubleshoot and repair many problems in electrical and electronic systems.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 3000 FC gives you true-RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 3000 FC provides higher 0.09% basic accuracy, a digital display showing up to three secondary measurements from remote modules, and a bright white backlight.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWork safely near electrical panels while wearing less PPE\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 3000 FC True-RMS Wireless Multimeter and Fluke Connect wireless test tools put tools, not your body, near live electrical panels. It's simple. Just de-energize the cabinet, open the panel while wearing PPE and connect the remote modules, whether they are voltage modules, current clamps, flexible current loops or thermometers. Then read the results on the 3000 FC Wireless Multimeter from a safe distance. You can display the meter measurement, plus readings from up to 3 wireless modules, while reducing the risk of arc flash by separating yourself from hazardous measurement situations.\u003c\/p\u003e\n\u003cp\u003eBetter still, the Fluke 3000 FC Series Wireless Multimeter can send measurement data to your smartphone, so you can save and share measurements from the field with your team anytime, from anywhere.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDon't get bogged down while chasing interrelated events\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eTiming is everything when trying to find the cause of a complex problem. Often you need to make a measurement in one place and see activity on a different part of the system at the same time. We've solved that problem with Fluke Connect - connect your remote modules in one location, then take your measurements up to 20 meters away with the Fluke 3000 FC multimeter. You'll be able to see the interaction between your remote test points on one single screen, in real time. You can even download the data to a PC for further analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOther capabilities of Fluke Connect and the FC 3000 Multimeter\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdd your laptop and go from logging to analysis and diagnosis.\u003c\/li\u003e\n\u003cli\u003eRecord over time using the Fluke Connect wireless modules and monitor circuit load changes for an hour, a shift or a week.\u003c\/li\u003e\n\u003cli\u003eUse the Fluke Connect wireless USB adapter to collect logged data from remote modules by walking past a working module and downloading logged data.\u003c\/li\u003e\n\u003cli\u003ePerform for analysis with your PC and share the results using Fluke Cloud™ storage and ShareLive™ video call. View data or graphs to get input from team members.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cdiv\u003e\n\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cdiv\u003e\n\u003cp\u003eThe Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC voltage measurements to 1000V\u003c\/li\u003e\n\u003cli\u003eAC and DC current with 0.01 mA resolution\u003c\/li\u003e\n\u003cli\u003eContinuity, resistance, diode test, capacitance and frequency measurements\u003c\/li\u003e\n\u003cli\u003eMIN\/MAX Recording\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, Cat IV 600 V; IP54\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePlus, the Fluke Connect wireless enabled modules measure AC, DC and AC+DC voltage, AC and DC current, plus temperature, all of which display on the Fluke 3000 FC Series Wireless Multimeter. Choose a standard clamp or flexible clamp to measure AC current. Mix and match modules to suit your unique measurement needs. Read the primary measurement on the main display and up to three modules at any one time. Modules are available separately or as part of Fluke Connect kits.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eAC Voltage\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange¹ \/ resolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003cbr\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003cspan\u003e2\u003c\/span\u003e \u003cspan\u003e3\u003c\/span\u003e \u003cspan\u003e4\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e45 Hz to 500 Hz\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e1. AC voltage ranges are specified from 1% of range to 100% of range. \u003cbr\u003e2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor \u0026lt; 1.5 at 1000 V.\u003cbr\u003e3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3. \u003cbr\u003e4. Do not exceed 107 V-Hz.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eDC Voltage, Continuity, Resistance, Diode Test and Capacitance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emV\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.09% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eV\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V \u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.09% + 2\u003cbr\u003e0.15% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e)))\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eMeter beeps at \u0026lt; 25 Ω, beeper detects opens or shorts of 250 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eΩ\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e60.00 kΩ \/ 0.1 kΩ\u003cbr\u003e600.0 kΩ \/ 0.001 MΩ\u003cbr\u003e50.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2\u003cbr\u003e0.5% + 1\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eµF\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF\u003cspan\u003e1 \/ \u003c\/span\u003e1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.2% + 2\u003cbr\u003e10% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eAC and DC Current\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA AC \u003cbr\u003e(45 Hz to 1 kHz)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eRange\u003cspan\u003e1\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e \/ resolution\u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA\u003cspan\u003e3 \u003c\/span\u003e\/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA DC\u003cspan\u003e2\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eRange\u003cspan\u003e1\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e \/ resolution\u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA\u003cspan\u003e3\u003c\/span\u003e \/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e1. All AC current ranges are specified from 5% of range to 100% of range. \u003cbr\u003e2. Input burden voltage (typical): 400 mA input 2 mV\/mA. \u003cbr\u003e3. 400.0 mA accuracy specified up to 600 mA overload.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eFrequency\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange \/ resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 kHz\u003cbr\u003e99.99 kHz \/ 0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003cspan\u003e1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eInput Characteristics\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/function-1.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio \u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/function-2.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio \u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB, DC to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/function-3.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio \u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eOpen Circuit Test Voltage\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/function-4.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale voltage to 6 MΩ\u003cbr\u003eFull scale voltage 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 V DC\u003cbr\u003e\u0026lt; 0.9 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/function-5.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":67636274233558,"sku":"Fluke 3000 FC","price":0.0,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/5800\/4694\/files\/F-3000fc_03a_600x402-500x554.jpg?v=1792320258","url":"https:\/\/safebox.sa\/en\/products\/mejdaf-691","provider":"SafeBox Company - شركة الصندوق الامن","version":"1.0","type":"link"}