{"product_id":"mejdaf-741","title":"Fluke 975 AirMeterTM","description":"\u003cp\u003e\u003cb\u003eOne Tool. Get More Done.\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eThe Fluke 975 AirMeter test tool raises indoor air monitoring to the next level by combining five powerful tools in one, rugged and easy-to-use handheld device. Use the Fluke 975 to optimize HVAC ventilation settings for ASHRAE 62 recommendations, actively monitor conditions that promote a productive environment, and quickly and accurately address occupant comfort complaints the first time.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThe Fluke 975 measures:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eVelocity\u003c\/li\u003e\n\u003cli\u003eHumidity\u003c\/li\u003e\n\u003cli\u003eCO\u003cspan\u003e2\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eCO\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eUse the Fluke 975 AirMeter test tool to:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRespond to comfort-related calls from occupants.\u003c\/li\u003e\n\u003cli\u003eVerify the operation of building HVAC control systems.\u003c\/li\u003e\n\u003cli\u003eDetermine whether adequate ventilation exists.\u003c\/li\u003e\n\u003cli\u003eMonitor air flow and velocity.\u003c\/li\u003e\n\u003cli\u003eTest for dangerous carbon monoxide leaks.\u003c\/li\u003e\n\u003cli\u003ePerform duct traversals.\u003c\/li\u003e\n\u003cli\u003eOptimize HVAC systems to manage energy costs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cli\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cb\u003eThe Fluke 975 offers an unparalleled featureset for HVAC and facilities technicians, helping them work more quickly and accurately, with the ease of use and durability customers expect from a Fluke meter\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp\u003eSimultaneously measures, logs, and displays temperature, humidity, CO\u003cspan\u003e2\u003c\/span\u003e, and CO on a bright, backlit LCD display\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne-touch air flow and velocity with available probe*\u003c\/li\u003e\n\u003cli\u003eWet bulb and dew point temperature\u003c\/li\u003e\n\u003cli\u003e% of outside air calculation\u003c\/li\u003e\n\u003cli\u003eCO\u003cspan\u003e2\u003c\/span\u003e and CO field calibration feature\u003c\/li\u003e\n\u003cli\u003eSelf-test function at startup\u003c\/li\u003eAuto-backlight\u003cli\u003eAutomatically compensates for barometric pressure changes\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average on all measured and calculated readings\u003c\/li\u003e\n\u003cli\u003eMulti-language user interface\u003c\/li\u003e\n\u003cli\u003eMetric or standard units\u003c\/li\u003e\n\u003cli\u003eAudible and visual threshold alarms\u003c\/li\u003e\n\u003cli\u003eExtensive discrete or continuous data logging capacity, downloadable to PC via USB interface\u003c\/li\u003e\n\u003cli\u003eKeypad lock for security\u003c\/li\u003e\n\u003cli\u003eIncluded FlukeView Forms® software\u003c\/li\u003e\n\u003cli\u003e*Included with Fluke 975V, optional with Fluke 975\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/li\u003e\u003cli\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eMeasured Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C (-5°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.9°C \/ ±1.62°F from 40°C to 60°C\u003cbr\u003e±0.5°C \/ ±1.00°F from 5°C to 40°C\u003cbr\u003e±1.1°C \/ ±1.98°F from -20°C to 5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2% RH (10% RH to 90% RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAir velocity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50.0 fpm to 3000 fpm\u003cbr\u003e0.25 m\/sec to 15 m\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e1 fpm (0.005 m\/sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±4% or 4 fpm\u003cspan\u003e1\u003c\/span\u003e\u003cbr\u003e±4% or 0.02 m\/sec\u003cspan\u003e1\u003c\/span\u003e whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e1. Accuracy specification only valid for velocity readings above 50 fpm.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eC0\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% or ±3 ppm, whichever is greater, @ 20°C and\u003cbr\u003e50% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eC0\u003cspan\u003e2\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eWarm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eCalculated Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDew point temperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-44°C to 50°C, (-47°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1°C when temp: -20°C to 50°C RH: 40% to 90%\u003cbr\u003e±2°C when temp: -20°C to 50°C RH: 20% to 40%\u003cbr\u003e±4°C when RH: 10% to 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWet bulb temperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-16°C to 50°C, (3°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C, (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.2°C when RH: 20% to 90% temp: -20°C to 60°C\u003cbr\u003e±2.1°C when RH: 10% to 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVolume flow rate (in a duct)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 3,965 M3\/m, (0 to 140,000 cfm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 M3\/min, (1 cfm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eN\/A: The volume flow calculation will be a simple average of the data points times the duct area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e% outside air (based on temperature)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e% outside air (based on CO\u003cspan\u003e2\u003c\/span\u003e)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.1% N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating and storage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 50°C (-4°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% to 90% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUp to 2000 m (6562 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock and vibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMIL-PRF-28800F: Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-language interface\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEnglish, French, Spanish, Portuguese and German\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRechargeable Li-Ion (primary), three-AA (backup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData logging\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e25,000 records (continuous), 99 records (discrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTwo-years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cul\u003e\u003cli\u003e\u003cul\u003e\u003cli\u003e\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eTitle\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke 975 Data Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/media.fluke.com\/documents\/2694296_0000_ENG_B_W.PDF\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":67636275216598,"sku":"Fluke 975","price":4485.0,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/5800\/4694\/files\/f-975-01c-s-600x402-500x554.jpg?v=1792320307","url":"https:\/\/safebox.sa\/en\/products\/mejdaf-741","provider":"SafeBox Company - شركة الصندوق الامن","version":"1.0","type":"link"}