{"product_id":"mejdaf-1010","title":"Fluke VR1710 Single Phase Voltage Quality Recorder","description":"\u003cp\u003eThe Fluke VR1710 Power Quality Recorder, is a single-phase, plug-in voltage quality recorder that offers an extremely easy-to-use solution for detecting and recording power quality problems, allowing for immediate action and less downtime. The VR1710 single phase recorder satisfies the needs of maintenance and facilities management personnel in industrial, utilities, and large service organizations where reliable power quality is essential to the operation of the business. Power quality parameters including RMS average, transients, flicker, and harmonics up to the 32nd are recorded using a user-selected average period from 1 seconds to 20 minutes.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003csection\u003e\u003c\/section\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFast and easy recording of voltage trends, dropouts, and power quality – Easily pinpoint the root cause of single phase voltage problems\u003c\/li\u003e\n\u003cli\u003eExtremely easy to use – Plug directly into the mains power socket and capture data\u003c\/li\u003e\n\u003cli\u003eContinuous recording of all values with no gaps – Save testing time by getting the whole picture with one instrument that records both events and voltage\u003c\/li\u003e\n\u003cli\u003eClear graphical summary of data and quick overview of key power quality parameters – Take the guesswork out of diagnosing voltage quality problems\u003c\/li\u003e\n\u003cli\u003eMin, Max, and Average RMS values (1\/4 cycle) with time stamp – Quickly see what happened and when\u003c\/li\u003e\n\u003cli\u003eActual transient display (\u0026gt;100 μs) with time stamp – Identify power quality issues quickly with included graphical software\u003c\/li\u003e\n\u003cli\u003eFlicker recording to EN 61000-4-15, individual harmonic and THD values with trends – Easily identify if the problem is power quality or equipment related\u003c\/li\u003e\n\u003cli\u003eStatistical analysis of single phase voltage events - Reduces analysis time by tracking event quantities and magnitudes\u003c\/li\u003e\n\u003cli\u003eIncludes PowerLog software package for quick download, analysis, and automatic reporting – Save time by generating power quality reports automatically with pre-set templates\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e70 V to 280 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin\/Max\/Avg RMS value\u003c\/td\u003e\n\u003ctd\u003eResolution 0.125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of events\u003c\/td\u003e\n\u003ctd\u003e175,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDips\/interruptions\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime resolution\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage resolution\u003c\/td\u003e\n\u003ctd\u003e0.125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-voltages\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics measurement\u003c\/td\u003e\n\u003ctd\u003eEN 61000-4-7 (up to 32nd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlicker measurement\u003c\/td\u003e\n\u003ctd\u003eEN 61000-4-15\u003cbr\u003eand Delta V\/V%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNumber of recording channels\u003c\/td\u003e\n\u003ctd\u003e1 Phase to Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e2 Phase\/Neutral to Ground\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording time\u003c\/td\u003e\n\u003ctd\u003e1 day to 339 days depending on average time from 1 second to 20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransients\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e50 Hz ±1 Hz and 60 Hz ±1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety category rating\u003c\/td\u003e\n\u003ctd\u003eCAT II 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cul\u003e\u003cli\u003e\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eTitle\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Sheet for Model VR1710\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/media.fluke.com\/documents\/3094014_6112_ENG_A_W.PDF\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":67636281114838,"sku":"Fluke VR1710","price":8418.0,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/5800\/4694\/files\/vr1710-01a-600x402-500x554.jpg?v=1792320521","url":"https:\/\/safebox.sa\/products\/mejdaf-1010","provider":"SafeBox Company - شركة الصندوق الامن","version":"1.0","type":"link"}