{"product_id":"mejdaf-1011","title":"Earth Resistance \u0026 Resistivity Tester","description":"\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003eHigh test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003eAdvanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003eAutomatic and Manual selection of the Test Current Frequency in four bands (94\/105\/111\/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003eSeveral sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003eWarning for excessive noise and high Auxiliary Earth Spikes resistance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cimg src=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/earth\/images\/4106.jpg\"\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/images\/ce.gif\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003eLarge Graphic Display with backlight for readings in poorly illuminated areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003eUp to 800 measurement results can be saved in the memory and recalled on the display.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003eThe stored results can be transferred to a PC using the \"KEW Report\" software and a USB adaptor (Model 8212-USB) which are included.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003eRobust design with IP54 protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cimg src=\"https:\/\/www.kew-ltd.co.jp\/en\/common_img\/spacer.gif\"\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eEarth resistance\u003cbr\u003eRe\u003cbr\u003e(Rg at\u003cbr\u003eρ measurement)\u003c\/td\u003e\n\u003ctd\u003e2Ω\u003c\/td\u003e\n\u003ctd\u003e0.001Ω\u003c\/td\u003e\n\u003ctd\u003e0.03 - 2.099Ω\u003c\/td\u003e\n\u003ctd\u003e\n\u003cfont\u003e|\u003c\/font\u003e±2%rdg±0.03Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20Ω\u003c\/td\u003e\n\u003ctd\u003e0.01Ω\u003c\/td\u003e\n\u003ctd\u003e0.03 - 20.99Ω\u003c\/td\u003e\n\u003ctd rowspan=\"5\"\u003e\n\u003cfont\u003e|\u003c\/font\u003e±2%rdg±5dgt (*1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200Ω\u003c\/td\u003e\n\u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003ctd\u003e0.3 - 209.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000Ω\u003c\/td\u003e\n\u003ctd\u003e1Ω\u003c\/td\u003e\n\u003ctd\u003e3 - 2099Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20kΩ\u003c\/td\u003e\n\u003ctd\u003e10Ω\u003c\/td\u003e\n\u003ctd\u003e0.03k - 20.99kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200kΩ\u003c\/td\u003e\n\u003ctd\u003e100Ω\u003c\/td\u003e\n\u003ctd\u003e0.3k - 209.9kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth resistance\u003cbr\u003eRh, Rs\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e8% of Re+Rh+Rs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eEarth resistivity\u003cbr\u003eρ\u003c\/td\u003e\n\u003ctd\u003e2Ω\u003c\/td\u003e\n\u003ctd rowspan=\"6\"\u003e0.1Ω•m - 1Ω•m\u003cbr\u003eAutoranging\u003c\/td\u003e\n\u003ctd\u003e0.2 - 395.6Ω•m\u003c\/td\u003e\n\u003ctd rowspan=\"6\"\u003eρ=2×\u003cspan\u003eπ\u003c\/span\u003e×a×Rg (*2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20Ω\u003c\/td\u003e\n\u003ctd\u003e0.2 - 3956Ω•m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200Ω\u003c\/td\u003e\n\u003ctd\u003e20 - 39.56kΩ•m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000Ω\u003c\/td\u003e\n\u003ctd\u003e0.2 - 395.6kΩ•m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20kΩ\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e2.0 - 1999kΩ•m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e200kΩ\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSeries interference voltage\u003cbr\u003eUst (A.C only) (*3)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e50V\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0.1V\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 - 50.9Vrms\u003c\/td\u003e\n\u003ctd\u003e\n\u003cfont\u003e|\u003c\/font\u003e±2%rdg±2dgt (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cfont\u003e|\u003c\/font\u003e±3%rdg±2dgt (40 - 500Hz)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003cbr\u003eFst\u003c\/td\u003e\n\u003ctd\u003eAutoranging\u003c\/td\u003e\n\u003ctd\u003e0.1Hz\u003cbr\u003e1Hz\u003c\/td\u003e\n\u003ctd\u003e40Hz - 500Hz\u003c\/td\u003e\n\u003ctd\u003e\n\u003cfont\u003e|\u003c\/font\u003e±1%rdg±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eEarth resistance: Fall-of-potential method (currents and voltages measured via the Probes)\u003cbr\u003eMeasurement method of Earth Resistivity (ρ): Wenner 4-pole method\u003cbr\u003eSeries interference voltage (earth voltage): RMS Rectifier (between the E-S Terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory capacity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e800 data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eModel 8212-USB Optical Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDot-matrix 192×64 monochrome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range Indication\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\"OL\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ebetween E-S(P) and between E-H(C) terminals AC280V \/ 10 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ebetween the electrical circuit and enclosure AC3540V(50\/60Hz) \/ 5 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable standards\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2\u003cbr\u003eIEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDC12V : sizeAA manganese dry battery (R6) × 8\u003cbr\u003e(Auto power off: approx. 5 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e167(L) × 185(W) × 89(D) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eapprox. 900g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/measurement\/index.html#7229A\"\u003e7229A\u003c\/a\u003e (Earth precision measurement),\u003cbr\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/measurement\/index.html#7238A\"\u003e7238A\u003c\/a\u003e (Simplified measurement test leads),\u003cbr\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/option\/mparts.html#8032\"\u003e8032\u003c\/a\u003e (Auxiliary earth spikes [2 spiks\/set])×2 sets (4 spikes in total),\u003cbr\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/option\/mparts.html#8200-04\"\u003e8200-04\u003c\/a\u003e (Cord reel [4 pcs])×1 set,\u003cbr\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/option\/8212_USB.html\"\u003e8212-USB\u003c\/a\u003e (USB adaptor with \"KEW Report(Software)\"),\u003cbr\u003e9121 (Shoulder strap),\u003cbr\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/option\/case.html#9125\"\u003e9125\u003c\/a\u003e (Carrying case),\u003cbr\u003eR6 × 8, Instruction manual, Calibration certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/option\/8212_RS232C.html\"\u003e8212-RS232C\u003c\/a\u003e (RS232C adaptor with \"KEW Report(Software)\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/www.kew-ltd.co.jp\/en\/common_img\/spacer.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/www.kew-ltd.co.jp\/en\/common_img\/spacer.gif\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e(*1)\u003c\/td\u003e\n\u003ctd\u003eAuxiliary earth resistance is 100Ω with Rk correction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cimg src=\"https:\/\/www.kew-ltd.co.jp\/en\/common_img\/spacer.gif\"\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e(*2)\u003c\/td\u003e\n\u003ctd\u003eDepending on the measured Rg. Interval [a] between auxiliary earth spikes is 1.0 - 30.0m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cimg src=\"https:\/\/www.kew-ltd.co.jp\/en\/common_img\/spacer.gif\"\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e(*3)\u003c\/td\u003e\n\u003ctd\u003eThis instrument is NOT designed to measure line voltages on commercial powers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Kyoritsu","offers":[{"title":"Default Title","offer_id":67636281147606,"sku":"4106A","price":7882.56,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/5800\/4694\/files\/4106-500x554.jpg?v=1792320523","url":"https:\/\/safebox.sa\/products\/mejdaf-1011","provider":"SafeBox Company - شركة الصندوق الامن","version":"1.0","type":"link"}