{"product_id":"mejdaf-557","title":"Fluke 125 ScopeMeter® Oscilloscopes","description":"\u003cp\u003e\u003cb\u003eScopeMeter® 125: All the power of the 120-Series plus Industrial Bus Health Test capabilities and advanced power measurements on top\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe compact ScopeMeter® is the rugged solution for industrial troubleshooting and installation applications. It’s a truly integrated test tool, with \u003ca href=\"http:\/\/en-us.fluke.com\/products\/portable-oscilloscopes\/\"\u003eoscilloscope\u003c\/a\u003e, multimeter and 'paperless' recorder in one affordable, easy-to-use instrument. Find fast answers to problems in machinery, instrumentation, control and power systems. Based on the Fluke 120 series, the 125 has all the capabilities of the 124 ScopeMeter extended with the capability to measure and analyze the signal quality on the common industrial buses\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003csection\u003e\u003c\/section\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input 40 MHz or 20 MHz digital oscilloscope\u003c\/li\u003e\n\u003cli\u003eTwo 5,000 counts true-RMS digital multimeters\u003c\/li\u003e\n\u003cli\u003eAutomatic measurements\u003c\/li\u003e\n\u003cli\u003eA dual-input TrendPlot™ recorder\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation\u003c\/li\u003e\n\u003cli\u003eShielded test leads for oscilloscope, voltage, resistance and continuity measurements\u003c\/li\u003e\n\u003cli\u003e10:1 Voltage Probe for high frequency measurements\u003c\/li\u003e\n\u003cli\u003eUp to 7 hours battery operation\u003c\/li\u003e\n\u003cli\u003e600 V CAT III safety certified\u003c\/li\u003e\n\u003cli\u003eOptically-isolated interface for PC connection\u003c\/li\u003e\n\u003cli\u003eGives bus health and power measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn today’s complex systems, a meter measurement just doesn’t give enough detail to determine the cause of a fault. Signal anomalies, dropouts and glitches that might cause a machine to go down, are best displayed with an oscilloscope. The ScopeMeter 125 meets today’s need of simultaneously measuring and checking waveforms. The unique Connect-and-View™ triggering automatically displays stable waveforms of virtually any signal. It really is as easy as one-two-three!\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA three-in-one tool\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/media.fluke.com\/images\/120_dual_input.jpg\"\u003e\u003cbr\u003eDual-input measurement shows both meter reading and waveform at the same time today’s need of simultaneously\u003c\/div\u003e\n\u003cp\u003eThe ScopeMeter 125 combines a 40 or 20 MHz dual input digital storage oscilloscope, two true-RMS digital multimeters and a dual input TrendPlot™ recorder all in a compact, battery powered instrument. Leave all other test tools behind, the ScopeMeter 125 is the only tool you’ll need.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOne test lead measures all\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/media.fluke.com\/images\/120_starting_cap.jpg\"\u003e\u003cbr\u003eCheck the starting capacitor of a motor using the ScopeMeter 125\u003c\/div\u003e\n\u003cp\u003eHigh frequency waveform-, meter-, capacitance- and resistance-measurements as well as continuity checks are all covered by the shielded test leads. No time wasted finding or swapping leads. The included accessories allow hook-up at test objects of every dimension.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe confidence to do a better job\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/media.fluke.com\/images\/120_meas_menu.jpg\"\u003e\u003cbr\u003eOpen the measure menu and select from 26 scope- and meter-measurements\u003c\/div\u003e\n\u003cp\u003eWorking under time pressure and in cramped or difficult to reach locations means you want to focus on the job at hand, not on the test tool in your hand. Which is why the ScopeMeter 125 has Connect-and-View automatic triggering. You don’t have to worry about triggering and instrument settings, and you have all the information on screen to do the job right.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBattery powered mobility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eUp to seven hours of battery operation frees you from mains outlets for true on-the-move working. The handheld format and the weight of just 1.2 kg, make the instrument easy to carry and to fit comfortably in your hand. The rugged and drip proof case assures long life and reliable operation in the harshest industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFloating measurements, safety certified\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eWhile conventional oscilloscopes can only make measurements referenced to power line ground, the Fluke ScopeMeter 125 makes floating measurements so there is no risk of an accidental ground short circuit when making a connection. The ScopeMeter 125 and the included shielded test leads are safety certified for measurements on 600 V CAT III industrial power systems. And using the VPS40 probe, measurements up to 1000 V CAT II re fully supported! Via the optically isolated RS-232 or USB interface, the ScopeMeter 125 can be safely connected to a printer for direct print-out or to a PC for later analysis and documentation using FlukeView software.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eConnect-and-View™ triggering for an instant, stable display\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/media.fluke.com\/images\/123_cnv.jpg\"\u003e\u003cbr\u003eConnect-and-View captures even the most complex motor drive signals\u003c\/div\u003e\n\u003cp\u003eScope users know how difficult triggering can be. Wrong settings show unstable and sometimes wrong results. Fluke’s unique Connect-and-View recognizes signal patterns, and automatically sets up correct triggering. It provides a stable, reliable and repeatable display of virtually any signal – including motor drive and control signals – without you touching a button. Signal changes are instantly recognized and settings adjusted for a stable display. Benefit from the speed and convenience when measuring a number of test points in quick succession.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eUse TrendPlot™ to help find intermittents, fast\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/media.fluke.com\/images\/123_tpl.jpg\"\u003e\u003cbr\u003eCursors and zoom help you analyze the captured TrendPlot\u003c\/div\u003e\n\u003cp\u003eThe toughest faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it – your Fluke ScopeMeter test tool will. In this “paperless” recorder mode, you can plot the minimum and maximum peak values and average over time – up to 16 days. The two inputs can plot any combination of volts, amps, temperature, frequency and phase – with time and date stamp – to help lead you to the cause of those faults quickly.\u003c\/p\u003e\n\u003cp\u003eBased on the Fluke 124, the Fluke 125 offers additional test capabilities for measurements on industrial machinery and industrial buses.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the Fluke 125 offers the following additional capabilities for tests on industrial machinery:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Measurements for single phase and balanced 3-phase systems. The Fluke 125 can directly present you the Total Power (Watts), Apparent Power (VA), Reactive Power (VAR) and the Power Factor (PF), over a wide range of applied frequencies, including those seen with motor drives and inverters. As a result, you are able to easily see the effects on the various power measurements during start-up or under changing operational conditions. A current clamp is included as a standard.\u003c\/li\u003e\n\u003cli\u003eHarmonics mode graphically displays harmonics up to the 33rd harmonic to assist in fault-finding, e.g. with large non-linear loads.\u003c\/li\u003e\n\u003cli\u003eRPM and Hz reading for use with electrical and combustion engines.\u003c\/li\u003e\n\u003cli\u003eVac pwm for use on motor drive outputs, reading the true output voltage experienced by the motor itself.\u003c\/li\u003e\n\u003cli\u003eLow impedance measurements giving a 0.01 ohms resolution for motor windings and the like.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eFlukeView® Software for documenting, archiving and analysis\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/120_pc_screen.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003eFlukeView® for Windows® helps you get more out of your ScopeMeter test tool by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDocumenting – transfer waveforms, screens and measurement data to a PC. Print or import the data into your report.\u003c\/li\u003e\n\u003cli\u003eAdd user text to individual ScopeMeter test tool settings – providing guidance to the operator when recalling a set-up.\u003c\/li\u003e\n\u003cli\u003eArchiving – create a library of waveforms with your comments for easy reference and comparison. Store complete Replay cycles for analysis of waveform changes. Store complete memory content of the ScopeMeter instrument on your PC for back-up purposes.\u003c\/li\u003e\n\u003cli\u003eWaveform Compare – store reference waveforms on the PC, or send a reference back to the ScopeMeter test tool for waveform comparison and “Pass\/Fail” testing.\u003c\/li\u003e\n\u003cli\u003eAnalysis – use cursors, perform spectrum analysis or export data to other analysis programs. ScopeMeter test tools are connected to a PC via an optically-isolated RS-232 or USB interface cable.\u003c\/li\u003e\n\u003cimg src=\"https:\/\/media.fluke.com\/images\/125bushealth.gif\"\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eAdditional features of the Fluke 125\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 125 is based on the Fluke 124 and includes all the functions and capabilities of that instrument. On top, a Bus Health Test mode allows for an analysis of the signal quality on industrial buses and networks, comparing measured signals to the standards’ signal requirements.\u003c\/p\u003e\n\u003cp\u003eThis section presents the Bus Health Test capabilities of the Fluke 125 specifically.\u003c\/p\u003e\n\u003cp\u003eFluke 125 is the portable oscilloscope of choice for the maintenance engineer who deals with industrial machinery and the industrial network connecting his machinery the like.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/scm125busasi.gif\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 125 has all the functionality of the Fluke 124 plus it comes with the following extensions: Bus Health mode gives a clear “Good” \/ “Weak” \/ “Bad” indication for the electrical signals on industrial buses and networks, such as CAN-bus, Profi-bus, RS-232 and many more. The Fluke 125 validates the quality of the electrical signals as soon as any electrical signals are passed along the network. It checks the signal levels and speed, transition times and distortion, and compares these to the appropriate standards to help you find errors like improper cable connections and terminators. It helps you find the source of error in case communication comes to a halt. All the commonly found industrial network types are supported!\u003c\/p\u003e\n\u003cp\u003eThe Fluke 125 also offers advanced power measurements for single phase and balanced 3-phase systems, a Harmonics Mode and more.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003csection\u003e\u003c\/section\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOscilloscope bandwidth\u003c\/td\u003e\n\u003ctd\u003e40 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual input true RMS meter\u003c\/td\u003e\n\u003ctd\u003eVDC, VAC, VAC + VDC, Ohms,Continuity, Diode-test Current, °C, °F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrendPlot recording\u003c\/td\u003e\n\u003ctd\u003eAutomatic vertical scaling and time compression\u003cbr\u003eDisplay the actual, MIN, MAX and AVG reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCursors\u003c\/td\u003e\n\u003ctd\u003eFluke 125\/124: ∆T, 1\/∆T, V, ∆V, rise- and fall time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample rate\u003c\/td\u003e\n\u003ctd\u003e2.5 GS\/s repetitive sampling\u003cbr\u003e25 MS\/s single shot sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs and digitizers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimebase range\u003c\/td\u003e\n\u003ctd\u003e20 ns - 1 min\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput sensitivity\u003c\/td\u003e\n\u003ctd\u003e5 mV - 500 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger types\u003c\/td\u003e\n\u003ctd\u003eConnect-and-View™, Free Run, Single Shot, Edge, Video, External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlitch capture\u003c\/td\u003e\n\u003ctd\u003e40 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope measurements\u003c\/td\u003e\n\u003ctd\u003eAutomatic measurements: 26 (all instruments) On top, Fluke 125 has additional measurement functions for Power (W), VA, VAR and Power Factor (PF) for single phase and balanced-three-phase (delta) power systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics mode\u003c\/td\u003e\n\u003ctd\u003eCapability to analyze the harmonics contents of power signals\u003cbr\u003e(see Harmonics Mode Section below for details)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum record length\u003c\/td\u003e\n\u003ctd\u003e512 min\/max pts per input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e20 screens and setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cspan\u003eAdditional Power Measurement Capabilities\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement types\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003eWatt,\u003c\/li\u003e\n\u003cli\u003eVA\u003c\/li\u003e\n\u003cli\u003eVAR,\u003c\/li\u003e\n\u003cli\u003ePower Factor (PF)\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower configuration\u003c\/td\u003e\n\u003ctd\u003eSingle phase or balanced three-phase (delta-configuration) mains supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage measurement\u003c\/td\u003e\n\u003ctd\u003eChannel A; using STL120, voltage probe or direct input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent measurement\u003c\/td\u003e\n\u003ctd\u003eChannel B, using i400s (included) or other compatible current clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent clamp or\u003cbr\u003eshunt sensitivity\u003c\/td\u003e\n\u003ctd\u003e0.1 \/ 1 \/ 10 \/ 100 \/ 1000 mV\/A, 10 mV\/mA and 400 mV\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cspan\u003eHarmonics mode\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eConverts waveform information into a harmonics display (using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyzed waveform\u003c\/td\u003e\n\u003ctd\u003eVoltage waveform(Ch.A), Current wavefrom (Ch.B) or Power (Ch.A x Ch.B), automatically generated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics frequency range\u003c\/td\u003e\n\u003ctd\u003eDC up to 33rd harmonic (for fundamental up to 60 Hz);\u003cbr\u003eDC up to 24th harmonic (for fundamental up to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eBargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurements\u003c\/td\u003e\n\u003ctd\u003eRelative amplitude of individual harmonics;\u003cbr\u003eTHD in %r or %f\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cspan\u003eBus Health Test Functions\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus health test\u003c\/td\u003e\n\u003ctd\u003eVerifies the electrical parameters of industrial bus systems using automatic measurement and analysis functions. Next to that, an Eyepattern mode is provided for visual inspection of signal quality.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter classification\u003c\/td\u003e\n\u003ctd\u003eDefault values:\u003cul\u003e\n\u003cli\u003ewell within limits = 'good'\u003c\/li\u003e\n\u003cli\u003ewithin certain percentage of the limit values = 'weak'\u003c\/li\u003e\n\u003cli\u003ebeyond limit values = 'bad'\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLimits values, as a default, are based on industry standard for the selected bus type or may be set by the user.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus systems supported\u003c\/td\u003e\n\u003ctd\u003eAS-i (EN50295, 166 kb\/s);\u003cbr\u003eCAN-bus (ISO-11898, up to 1 Mb\/s);\u003cbr\u003eInterbus S (EIA-485, 500 kb\/s);\u003cbr\u003eControlNet (61158 type 2, 5Mb\/s);\u003cbr\u003eModbus (EIA-232 up to 115 kb\/s and \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":67636272169174,"sku":"Fluke 125","price":20286.0,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/5800\/4694\/files\/125-600x402-500x554.jpg?v=1792320162","url":"https:\/\/safebox.sa\/products\/mejdaf-557","provider":"SafeBox Company - شركة الصندوق الامن","version":"1.0","type":"link"}