{"product_id":"mejdaf-722","title":"Fluke 87V\/E2 Industrial Electrician Combo Kit","description":"\u003cp\u003eThis combo kit is built around the Fluke 87V, the most widely used industrial digital multimeter in the world, and includes special accessories to make you even more productive on the job. This kit will save over 15% compared with the individual price of all the accessories. Plus you'll be working with the most trusted tools in the world.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003csection\u003e\u003c\/section\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eUnique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument\u003c\/li\u003e\n\u003cli\u003eOptional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks\u003c\/li\u003e\n\u003cli\u003eLarge digit display with bright, two-level backlight makes the 87V significantly easier to read than older models\u003c\/li\u003e\n\u003cli\u003eTrue-rms ac voltage and current for accurate measurements on non linear signals\u003c\/li\u003e\n\u003cli\u003eSelectable filter for accurate voltage and frequency measurements on motor drives\u003c\/li\u003e\n\u003cli\u003e0.05% DC accuracy\u003c\/li\u003e\n\u003cli\u003e6000 counts, 3-3\/4 digits\u003c\/li\u003e\n\u003cli\u003e4-1\/2 digit mode for precise measurements (20,000 counts)\u003c\/li\u003e\n\u003cli\u003eMeasure up to 1000 V AC and DC\u003c\/li\u003e\n\u003cli\u003eMeasure up to 10 A, 20 A for up to 30 seconds\u003c\/li\u003e\n\u003cli\u003eBuilt in thermometer lets you carry one less tool (TC probe included)\u003c\/li\u003e\n\u003cli\u003eFrequency to 200 kHz and % duty cycle\u003c\/li\u003e\n\u003cli\u003eResistance, continuity and diode test\u003c\/li\u003e\n\u003cli\u003e10,000 µF capacitance range for components and motor caps\u003c\/li\u003e\n\u003cli\u003eMin\/Max-Average recording with Min\/Max Alert to capture variations automatically\u003c\/li\u003e\n\u003cli\u003ePeak capture to record transients as fast as 250 µs\u003c\/li\u003e\n\u003cli\u003eRelative mode to remove test lead interference from low ohms measurements\u003c\/li\u003e\n\u003cli\u003eAuto and manual ranging for maximum flexibility\u003c\/li\u003e\n\u003cli\u003eTouch Hold to capture stable readings avoiding noisy signals\u003c\/li\u003e\n\u003cli\u003eLarge display digits and two-level bright white backlight for increased visibility\u003c\/li\u003e\n\u003cli\u003eAnalog bargraph for fast changing or unstable signals\u003c\/li\u003e\n\u003cli\u003eInput Alert provides audible warning against wrong use of input jacks\u003c\/li\u003e\n\u003cli\u003eImproved selectable sleep mode for long battery life\u003c\/li\u003e\n\u003cli\u003eAccess door for fast battery changes without breaking the calibration seal\u003c\/li\u003e\n\u003cli\u003e\"Classic\" design with new removable holster with built in test lead and probe storage\u003c\/li\u003e\n\u003cli\u003eLifetime warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/87V_06_200p.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eElectrical safety\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eAll inputs are protected to the 2nd edition of ANSI\/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCorrectly measure pulse-width modulated motor drive signals\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eUntil now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUnique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals\u003c\/li\u003e\n\u003cli\u003eAccurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency\u003c\/li\u003e\n\u003cli\u003eMeasure AC current with an optional current clamp accessory\u003c\/li\u003e\n\u003cli\u003eCompare reading from the 87V with the display on the ASD\u003c\/li\u003e\n\u003cli\u003eSpecial shielding blocks high frequency, high-energy noise generated by large drive systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/motordrive-AC-pulse_324p.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/media.fluke.com\/images\/motordrive-AC-sine_324p.gif\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplex PWM drive signals are not a problem for the Fluke 87V.\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePulse-width modulated detail of 50 Hz motor drive output voltage. 1000 V, 50 micro-second pulses can cause erratic behavior in some test equipment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cul\u003e\u003cli\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.05% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.7% + 2) True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Bandwidth\u003c\/td\u003e\n\u003ctd\u003e20 kHz with low pass filter; 3 db @ 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Amps\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Amps\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 2) True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Resistance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Capacitance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e9,999 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Frequency\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.005% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Duty Cycle\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% per khz +0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-200.0°C - 1090°C\u003cbr\u003e-328.0°F - 1994.0°F\u003cbr\u003eexcluding probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80 BK Temperature Probe\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40.0°C - 260°C\u003cbr\u003e-40.0°F - 500°F, 2.2°C or 2% whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eConductance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Conductance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e60.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDiode\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle Range\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±(02% per kHz +0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (Without Condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% - 90% (0°C - 35°C)\u003cbr\u003e0% - 70% (35°C - 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61010-1 to 1000 V CAT III, 600V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUL, CSA, TÜV, VDE listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e201 x 98 x 52 mm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e355 g\u003cbr\u003e624 g - with holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDigital\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 counts updates 4\/sec.\u003cbr\u003e19,999 counts in high-resolution mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog\u003c\/td\u003e\n\u003ctd\u003e32 segments, updates 40\/sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e19,999 counts, updates 3\/sec at \u0026gt; 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eWarranty\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/li\u003e\u003c\/ul\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":67636274954454,"sku":"87-V\/E2K","price":3933.0,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/5800\/4694\/files\/87v-e2-01c-600x402-500x554.jpg?v=1792320294","url":"https:\/\/safebox.sa\/products\/mejdaf-722","provider":"SafeBox Company - شركة الصندوق الامن","version":"1.0","type":"link"}